7.1. AuthorizationData

Class

Elements that constitute an entry of a Local Authorization List update.

FIELD NAMEFIELD TYPECARD.DESCRIPTION
idTagIdToken1..1Required. The identifier to which this authorization applies.
idTagInfoIdTagInfo0..1Optional. (Required when UpdateType is Full) This contains information about authorization status, expiry and parent id. For a Differential update the following applies: If this element is present, then this entry SHALL be added or updated in the Local Authorization List. If this element is absent, than the entry for this idtag in the Local Authorization List SHALL be deleted.

7.2. AuthorizationStatus

Enumeration

Status in a response to an Authorize.req.

VALUEDESCRIPTION
AcceptedIdentifier is allowed for charging.
BlockedIdentifier has been blocked. Not allowed for charging.
ExpiredIdentifier has expired. Not allowed for charging.
InvalidIdentifier is unknown. Not allowed for charging.
ConcurrentTxIdentifier is already involved in another transaction and multiple transactions are not allowed. (Only relevant for a StartTransaction.req.)

7.3. AvailabilityStatus

Enumeration

Status returned in response to ChangeAvailability.req.

VALUEDESCRIPTION
AcceptedRequest has been accepted and will be executed.
RejectedRequest has not been accepted and will not be executed.
ScheduledRequest has been accepted and will be executed when transaction(s) in progress have finished.

7.4. AvailabilityType

Enumeration

Requested availability change in ChangeAvailability.req.

VALUEDESCRIPTION
InoperativeCharge point is not available for charging.
OperativeCharge point is available for charging.

7.5. CancelReservationStatus

Enumeration

Status in CancelReservation.conf.

VALUEDESCRIPTION
AcceptedReservation for the identifier has been cancelled.
RejectedReservation could not be cancelled, because there is no reservation active for the identifier.

7.6. ChargePointErrorCode

Enumeration

Charge Point status reported in StatusNotification.req.

VALUEDESCRIPTION
ConnectorLockFailureFailure to lock or unlock connector.
EVCommunicationErrorCommunication failure with the vehicle, might be Mode 3 or other communication protocol problem. This is not a real error in the sense that the Charge Point doesn’t need to go to the faulted state. Instead, it should go to the SuspendedEVSE state.
GroundFailureGround fault circuit interrupter has been activated.
HighTemperatureTemperature inside Charge Point is too high.
InternalErrorError in internal hard- or software component.
LocalListConflictThe authorization information received from the Central System is in conflict with the LocalAuthorizationList.
NoErrorNo error to report.
OtherErrorOther type of error. More information in vendorErrorCode.
OverCurrentFailureOver current protection device has tripped.
OverVoltageVoltage has risen above an acceptable level.
PowerMeterFailureFailure to read electrical/energy/power meter.
PowerSwitchFailureFailure to control power switch.
ReaderFailureFailure with idTag reader.
ResetFailureUnable to perform a reset.
UnderVoltageVoltage has dropped below an acceptable level.
WeakSignalWireless communication device reports a weak signal.

7.7. ChargePointStatus

Enumeration

Status reported in StatusNotification.req. A status can be reported for the Charge Point main controller (connectorId = 0) or for a specific connector. Status for the Charge Point main controller is a subset of the enumeration: Available, Unavailable or Faulted.

States considered Operative are: Available, Preparing, Charging, SuspendedEVSE, SuspendedEV, Finishing, Reserved. States considered Inoperative are: Unavailable, Faulted.

STATUSCONDITION
AvailableWhen a Connector becomes available for a new user (Operative)
PreparingWhen a Connector becomes no longer available for a new user but there is no ongoing Transaction (yet). Typically a Connector is in preparing state when a user presents a tag, inserts a cable or a vehicle occupies the parking bay (Operative)
ChargingWhen the contactor of a Connector closes, allowing the vehicle to charge (Operative)
SuspendedEVSEWhen the EV is connected to the EVSE but the EVSE is not offering energy to the EV, e.g. due to a smart charging restriction, local supply power constraints, or as the result of StartTransaction.conf indicating that charging is not allowed etc. (Operative)
SuspendedEVWhen the EV is connected to the EVSE and the EVSE is offering energy but the EV is not taking any energy. (Operative)
FinishingWhen a Transaction has stopped at a Connector, but the Connector is not yet available for a new user, e.g. the cable has not been removed or the vehicle has not left the parking bay (Operative)
ReservedWhen a Connector becomes reserved as a result of a Reserve Now command (Operative)
UnavailableWhen a Connector becomes unavailable as the result of a Change Availability command or an event upon which the Charge Point transitions to unavailable at its discretion. Upon receipt of a Change Availability command, the status MAY change immediately or the change MAY be scheduled. When scheduled, the Status Notification shall be send when the availability change becomes effective (Inoperative)
FaultedWhen a Charge Point or connector has reported an error and is not available for energy delivery. (Inoperative).

7.8. ChargingProfile

Class

A ChargingProfile consists of a ChargingSchedule, describing the amount of power or current that can be delivered per time interval.

Figure 42. Class Diagram: ChargingProfile

FIELD NAMEFIELD TYPECARD.DESCRIPTION
chargingProfileIdinteger1..1Required. Unique identifier for this profile.
transactionIdinteger0..1Optional. Only valid if ChargingProfilePurpose is set to TxProfile, the transactionId MAY be used to match the profile to a specific transaction.
stackLevelinteger >=01..1Required. Value determining level in hierarchy stack of profiles. Higher values have precedence over lower values. Lowest level is 0.
chargingProfilePurposeChargingProfilePurposeType1..1Required. Defines the purpose of the schedule transferred by this message.
chargingProfileKindChargingProfileKindType1..1Required. Indicates the kind of schedule.
recurrencyKindRecurrencyKindType0..1Optional. Indicates the start point of a recurrence.
validFromdateTime0..1Optional. Point in time at which the profile starts to be valid. If absent, the profile is valid as soon as it is received by the Charge Point.
validTodateTime0..1Optional. Point in time at which the profile stops to be valid. If absent, the profile is valid until it is replaced by another profile.
chargingScheduleChargingSchedule1..1Required. Contains limits for the available power or current over time.

7.9. ChargingProfileKindType

Enumeration

Kind of charging profile, as used in: ChargingProfile.

VALUEDESCRIPTION
AbsoluteSchedule periods are relative to a fixed point in time defined in the schedule.
RecurringThe schedule restarts periodically at the first schedule period.
RelativeSchedule periods are relative to a situation-specific start point (such as the start of a Transaction) that is determined by the charge point.

7.10. ChargingProfilePurposeType

Enumeration

Purpose of the charging profile, as used in: ChargingProfile.

VALUEDESCRIPTION
ChargePointMaxProfileConfiguration for the maximum power or current available for an entire Charge Point.
TxDefaultProfileDefault profile *that can be configured in the Charge Point. When a new transaction is started, this profile SHALL be used, unless it was a transaction that was started by a RemoteStartTransaction.req with a ChargeProfile that is accepted by the Charge Point.
TxProfileProfile with constraints to be imposed by the Charge Point on the current transaction, or on a new transaction when this is started via a RemoteStartTransaction.req with a ChargeProfile. A profile with this purpose SHALL cease to be valid when the transaction terminates.

7.11. ChargingProfileStatus

Enumeration

Status returned in response to SetChargingProfile.req.

VALUEDESCRIPTION
AcceptedRequest has been accepted and will be executed.
RejectedRequest has not been accepted and will not be executed.
NotSupportedCharge Point indicates that the request is not supported.

7.12. ChargingRateUnitType

Enumeration

Unit in which a charging schedule is defined, as used in: GetCompositeSchedule.req and ChargingSchedule

VALUEDESCRIPTION
WWatts (power).
This is the TOTAL allowed charging power.
If used for AC Charging, the phase current should be calculated via: Current per phase = Power / (Line Voltage * Number of Phases). The "Line Voltage" used in the calculation is not the measured voltage, but the set voltage for the area (hence, 230 of 110 volt). The "Number of Phases" is the numberPhases from the ChargingSchedulePeriod.
It is usually more convenient to use this for DC charging.
Note that if numberPhases in a ChargingSchedulePeriod is absent, 3 SHALL be assumed.
AAmperes (current).
The amount of Ampere per phase, not the sum of all phases.
It is usually more convenient to use this for AC charging.

7.13. ChargingSchedule

Class

Charging schedule structure defines a list of charging periods, as used in: GetCompositeSchedule.conf and ChargingProfile.

FIELD NAMEFIELD TYPECARD.DESCRIPTION
durationinteger0..1Optional. Duration of the charging schedule in seconds. If the duration is left empty, the last period will continue indefinitely or until end of the transaction in case startSchedule is absent.
startScheduledateTime0..1Optional. Starting point of an absolute schedule. If absent the schedule will be relative to start of charging.
chargingRateUnitChargingRateUnitType1..1Required. The unit of measure Limit is expressed in.
chargingSchedulePeriodChargingSchedulePeriod1..*Required. List of ChargingSchedulePeriod elements defining maximum power or current usage over time. The startSchedule of the first ChargingSchedulePeriod SHALL always be 0.
minChargingRatedecimal0..1Optional. Minimum charging rate supported by the electric vehicle. The unit of measure is defined by the chargingRateUnit. This parameter is intended to be used by a local smart charging algorithm to optimize the power allocation for in the case a charging process is inefficient at lower charging rates. Accepts at most one digit fraction (e.g. 8.1)

7.14. ChargingSchedulePeriod

Class

Charging schedule period structure defines a time period in a charging schedule, as used in: ChargingSchedule.

FIELD NAMEFIELD TYPECARD.DESCRIPTION
startPeriodinteger1..1Required. Start of the period, in seconds from the start of schedule. The value of StartPeriod also defines the stop time of the previous period.
limitdecimal1..1Required. Charging rate limit during the schedule period, in the applicable chargingRateUnit, for example in Amperes or Watts. Accepts at most one digit fraction (e.g. 8.1).
numberPhasesinteger0..1Optional. The number of phases that can be used for charging. If a number of phases is needed, numberPhases=3 will be assumed unless another number is given.

7.15. CiString20Type

Type

Generic used case insensitive string of 20 characters.

FIELD TYPEDESCRIPTION
CiString[20]String is case insensitive.

7.16. CiString25Type

Type

Generic used case insensitive string of 25 characters.

FIELD TYPEDESCRIPTION
CiString[25]String is case insensitive.

7.17. CiString50Type

Type

Generic used case insensitive string of 50 characters.

FIELD TYPEDESCRIPTION
CiString[50]String is case insensitive.

7.18. CiString255Type

Type

Generic used case insensitive string of 255 characters.

FIELD TYPEDESCRIPTION
CiString[255]String is case insensitive.

7.19. CiString500Type

Type

Generic used case insensitive string of 500 characters.

FIELD TYPEDESCRIPTION
CiString[500]String is case insensitive.

7.20. ClearCacheStatus

Enumeration

Status returned in response to ClearCache.req.

VALUEDESCRIPTION
AcceptedCommand has been executed.
RejectedCommand has not been executed.

7.21. ClearChargingProfileStatus

Enumeration

Status returned in response to ClearChargingProfile.req.

VALUEDESCRIPTION
AcceptedRequest has been accepted and will be executed.
UnknownNo Charging Profile(s) were found matching the request.

7.22. ConfigurationStatus

Enumeration

Status in ChangeConfiguration.conf.

VALUEDESCRIPTION
AcceptedConfiguration key is supported and setting has been changed.
RejectedConfiguration key is supported, but setting could not be changed.
RebootRequiredConfiguration key is supported and setting has been changed, but change will be available after reboot (Charge Point will not reboot itself)
NotSupportedConfiguration key is not supported.

7.23. DataTransferStatus

Enumeration

Status in DataTransfer.conf.

VALUEDESCRIPTION
AcceptedMessage has been accepted and the contained request is accepted.
RejectedMessage has been accepted but the contained request is rejected.
UnknownMessageIdMessage could not be interpreted due to unknown messageId string.
UnknownVendorIdMessage could not be interpreted due to unknown vendorId string.

7.24. DiagnosticsStatus

Enumeration

Status in DiagnosticsStatusNotification.req.

VALUEDESCRIPTION
IdleCharge Point is not performing diagnostics related tasks. Status Idle SHALL only be used as in a DiagnosticsStatusNotification.req that was triggered by a TriggerMessage.req
UploadedDiagnostics information has been uploaded.
UploadFailedUploading of diagnostics failed.
UploadingFile is being uploaded.

7.25. FirmwareStatus

Enumeration

Status of a firmware download as reported in FirmwareStatusNotification.req.

VALUEDESCRIPTION
DownloadedNew firmware has been downloaded by Charge Point.
DownloadFailedCharge point failed to download firmware.
DownloadingFirmware is being downloaded.
IdleCharge Point is not performing firmware update related tasks. Status Idle SHALL only be used as in a FirmwareStatusNotification.req that was triggered by a TriggerMessage.req
InstallationFailedInstallation of new firmware has failed.
InstallingFirmware is being installed.
InstalledNew firmware has successfully been installed in charge point.

7.26. GetCompositeScheduleStatus

Enumeration

Status returned in response to GetCompositeSchedule.req.

VALUEDESCRIPTION
AcceptedRequest has been accepted and will be executed.
RejectedRequest has not been accepted and will not be executed.

7.27. IdTagInfo

Class

Contains status information about an identifier. It is returned in Authorize, Start Transaction and Stop Transaction responses.

If expiryDate is not given, the status has no end date.

FIELD NAMEFIELD TYPECARD.DESCRIPTION
expiryDatedateTime0..1Optional. This contains the date at which idTag should be removed from the Authorization Cache.
parentIdTagIdToken0..1Optional. This contains the parent-identifier.
statusAuthorizationStatus1..1Required. This contains whether the idTag has been accepted or not by the Central System.

7.28. IdToken

Type

Contains the identifier to use for authorization. It is a case insensitive string. In future releases this may become a complex type to support multiple forms of identifiers.

FIELD TYPEDESCRIPTION
CiString20TypeIdToken is case insensitive.

7.29. KeyValue

Class

Contains information about a specific configuration key. It is returned in GetConfiguration.conf.

NAMEFIELD TYPECARD.DESCRIPTION
keyCiString50Type1..1Required.
readonlyboolean1..1Required. False if the value can be set with the ChangeConfiguration message.
valueCiString500Type0..1Optional. If key is known but not set, this field may be absent.

7.30. Location

Enumeration

Allowable values of the optional "location" field of a value element in SampledValue.

VALUEDESCRIPTION
BodyMeasurement inside body of Charge Point (e.g. Temperature)
CableMeasurement taken from cable between EV and Charge Point
EVMeasurement taken by EV
InletMeasurement at network (“grid”) inlet connection
OutletMeasurement at a Connector. Default value

7.31. Measurand

Enumeration

Allowable values of the optional "measurand" field of a Value element, as used in MeterValues.req and StopTransaction.req messages. Default value of "measurand" is always "Energy.Active.Import.Register"

note

Import is energy flow from the Grid to the Charge Point, EV or other load. Export is energy flow from the EV to the Charge Point and/or from the Charge Point to the Grid.

VALUEDESCRIPTION
Current.ExportInstantaneous current flow from EV
Current.ImportInstantaneous current flow to EV
Current.OfferedMaximum current offered to EV
Energy.Active.Export.RegisterNumerical value read from the "active electrical energy" (Wh or kWh) register of the (most authoritative) electrical meter measuring energy exported (to the grid).
Energy.Active.Import.RegisterNumerical value read from the "active electrical energy" (Wh or kWh) register of the (most authoritative) electrical meter measuring energy imported (from the grid supply).
Energy.Reactive.Export.RegisterNumerical value read from the "reactive electrical energy" (VARh or kVARh) register of the (most authoritative) electrical meter measuring energy exported (to the grid).
Energy.Reactive.Import.RegisterNumerical value read from the "reactive electrical energy" (VARh or kVARh) register of the (most authoritative) electrical meter measuring energy imported (from the grid supply).
Energy.Active.Export.IntervalAbsolute amount of "active electrical energy" (Wh or kWh) exported (to the grid) during an associated time "interval", specified by a Metervalues ReadingContext, and applicable interval duration configuration values (in seconds) for "ClockAlignedDataInterval" and "MeterValueSampleInterval".
Energy.Active.Import.IntervalAbsolute amount of "active electrical energy" (Wh or kWh) imported (from the grid supply) during an associated time "interval", specified by a Metervalues ReadingContext, and applicable interval duration configuration values (in seconds) for "ClockAlignedDataInterval" and "MeterValueSampleInterval".
Energy.Reactive.Export.IntervalAbsolute amount of "reactive electrical energy" (VARh or kVARh) exported (to the grid) during an associated time "interval", specified by a Metervalues ReadingContext, and applicable interval duration configuration values (in seconds) for "ClockAlignedDataInterval" and "MeterValueSampleInterval".
Energy.Reactive.Import.IntervalAbsolute amount of "reactive electrical energy" (VARh or kVARh) imported (from the grid supply) during an associated time "interval", specified by a Metervalues ReadingContext, and applicable interval duration configuration values (in seconds) for "ClockAlignedDataInterval" and "MeterValueSampleInterval".
FrequencyInstantaneous reading of powerline frequency. NOTE: OCPP 1.6 does not have a UnitOfMeasure for frequency, the UnitOfMeasure for any SampledValue with measurand: Frequency is Hertz.
Power.Active.ExportInstantaneous active power exported by EV. (W or kW)
Power.Active.ImportInstantaneous active power imported by EV. (W or kW)
Power.FactorInstantaneous power factor of total energy flow
Power.OfferedMaximum power offered to EV
Power.Reactive.ExportInstantaneous reactive power exported by EV. (var or kvar)
Power.Reactive.ImportInstantaneous reactive power imported by EV. (var or kvar)
RPMFan speed in RPM
SoCState of charge of charging vehicle in percentage
TemperatureTemperature reading inside Charge Point.
VoltageInstantaneous AC RMS supply voltage
note

All "Register" values relating to a single charging transaction, or a non-transactional consumer (e.g. charge point internal power supply, overall supply) MUST be monotonically increasing in time.

The actual quantity of energy corresponding to a reported ".Register" value is computed as the register value in question minus the register value recorded/reported at the start of the transaction or other relevant starting reference point in time. For improved auditability, ".Register" values SHOULD reported exactly as they are directly read from a non-volatile register in the electrical metering hardware, and SHOULD NOT be re-based to zero at the start of transactions. This allows any "missing energy" between sequential transactions, due to hardware fault, mis-wiring, fraud, etc. to be identified, by allowing the Central System to confirm that the starting register value of any transaction is identical to the finishing register value of the preceding transaction on the same connector.

7.32. MessageTrigger

Enumeration

Type of request to be triggered in a TriggerMessage.req.

VALUEDESCRIPTION
BootNotificationTo trigger a BootNotification request
DiagnosticsStatusNotificationTo trigger a DiagnosticsStatusNotification request
FirmwareStatusNotificationTo trigger a FirmwareStatusNotification request
HeartbeatTo trigger a Heartbeat request
MeterValuesTo trigger a MeterValues request
StatusNotificationTo trigger a StatusNotification request

7.33. MeterValue

Class

Collection of one or more sampled values in MeterValues.req and StopTransaction.req. All sampled values in a MeterValue are sampled at the same point in time.

FIELD NAMEFIELD TYPECARD.DESCRIPTION
timestampdateTime1..1Required. Timestamp for measured value(s).
sampledValueSampledValue1..*Required. One or more measured values

7.34. Phase

Enumeration

Phase as used in SampledValue. Phase specifies how a measured value is to be interpreted. Please note that not all values of Phase are applicable to all Measurands.

VALUEDESCRIPTION
L1Measured on L1
L2Measured on L2
L3Measured on L3
NMeasured on Neutral
L1-NMeasured on L1 with respect to Neutral conductor
L2-NMeasured on L2 with respect to Neutral conductor
L3-NMeasured on L3 with respect to Neutral conductor
L1-L2Measured between L1 and L2
L2-L3Measured between L2 and L3
L3-L1Measured between L3 and L1

7.35. ReadingContext

Enumeration

Values of the context field of a value in SampledValue.

VALUEDESCRIPTION
Interruption.BeginValue taken at start of interruption.
Interruption.EndValue taken when resuming after interruption.
OtherValue for any other situations.
Sample.ClockValue taken at clock aligned interval.
Sample.PeriodicValue taken as periodic sample relative to start time of transaction.
Transaction.BeginValue taken at start of transaction.
Transaction.EndValue taken at end of transaction.
TriggerValue taken in response to a TriggerMessage.req

7.36. Reason

Enumeration

Reason for stopping a transaction in StopTransaction.req.

VALUEDESCRIPTION
DeAuthorizedThe transaction was stopped because of the authorization status in a StartTransaction.conf
EmergencyStopEmergency stop button was used.
EVDisconnecteddisconnecting of cable, vehicle moved away from inductive charge unit.
HardResetA hard reset command was received.
LocalStopped locally on request of the user at the Charge Point. This is a regular termination of a transaction. Examples: presenting an RFID tag, pressing a button to stop.
OtherAny other reason.
PowerLossComplete loss of power.
RebootA locally initiated reset/reboot occurred. (for instance watchdog kicked in)
RemoteStopped remotely on request of the user. This is a regular termination of a transaction. Examples: termination using a smartphone app, exceeding a (non local) prepaid credit.
SoftResetA soft reset command was received.
UnlockCommandCentral System sent an Unlock Connector command.

7.37. RecurrencyKindType

Enumeration

Type of recurrence of a charging profile, as used in ChargingProfile.

VALUEDESCRIPTION
DailyThe schedule restarts every 24 hours, at the same time as in the startSchedule.
WeeklyThe schedule restarts every 7 days, at the same time and day-of-the-week as in the startSchedule.

7.38. RegistrationStatus

Enumeration

Result of registration in response to BootNotification.req.

VALUEDESCRIPTION
AcceptedCharge point is accepted by Central System.
PendingCentral System is not yet ready to accept the Charge Point. Central System may send messages to retrieve information or prepare the Charge Point.
RejectedCharge point is not accepted by Central System. This may happen when the Charge Point id is not known by Central System.

7.39. RemoteStartStopStatus

Enumeration

The result of a RemoteStartTransaction.req or RemoteStopTransaction.req request.

VALUEDESCRIPTION
AcceptedCommand will be executed.
RejectedCommand will not be executed.

7.40. ReservationStatus

Enumeration

Status in ReserveNow.conf.

VALUEDESCRIPTION
AcceptedReservation has been made.
FaultedReservation has not been made, because connectors or specified connector are in a faulted state.
OccupiedReservation has not been made. All connectors or the specified connector are occupied.
RejectedReservation has not been made. Charge Point is not configured to accept reservations.
UnavailableReservation has not been made, because connectors or specified connector are in an unavailable state.

7.41. ResetStatus

Enumeration

Result of Reset.req.

VALUEDESCRIPTION
AcceptedCommand will be executed.
RejectedCommand will not be executed.

7.42. ResetType

Enumeration

Type of reset requested by Reset.req.

VALUEDESCRIPTION
HardRestart (all) the hardware, the Charge Point is not required to gracefully stop ongoing transaction. If possible the Charge Point sends a StopTransaction.req for previously ongoing transactions after having restarted and having been accepted by the Central System via a BootNotification.conf. This is a last resort solution for a not correctly functioning Charge Point, by sending a "hard" reset, (queued) information might get lost.
SoftStop ongoing transactions gracefully and sending StopTransaction.req for every ongoing transaction. It should then restart the application software (if possible, otherwise restart the processor/controller).

7.43. SampledValue

Class

Single sampled value in MeterValues. Each value can be accompanied by optional fields.

FIELD NAMEFIELD TYPECARD.DESCRIPTION
valueString1..1Required. Value as a “Raw” (decimal) number or “SignedData”. Field Type is “string” to allow for digitally signed data readings. Decimal numeric values are also acceptable to allow fractional values for measurands such as Temperature and Current.
contextReadingContext0..1Optional. Type of detail value: start, end or sample. Default = “Sample.Periodic”
formatValueFormat0..1Optional. Raw or signed data. Default = “Raw”
measurandMeasurand0..1Optional. Type of measurement. Default = “Energy.Active.Import.Register”
phasePhase0..1Optional. indicates how the measured value is to be interpreted. For instance between L1 and neutral (L1-N) Please note that not all values of phase are applicable to all Measurands. When phase is absent, the measured value is interpreted as an overall value.
locationLocation0..1Optional. Location of measurement. Default=”Outlet”
unitUnitOfMeasure0..1Optional. Unit of the value. Default = “Wh” if the (default) measurand is an “Energy” type.

7.44. TriggerMessageStatus

Enumeration

Status in TriggerMessage.conf.

VALUEDESCRIPTION
AcceptedRequested notification will be sent.
RejectedRequested notification will not be sent.

7.45. UnitOfMeasure

Enumeration

Allowable values of the optional "unit" field of a Value element, as used in SampledValue. Default value of "unit" is always "Wh".

VALUEDESCRIPTION
WhWatt-hours (energy). Default.
kWhkiloWatt-hours (energy).
varhVar-hours (reactive energy).
kvarhkilovar-hours (reactive energy).
WWatts (power).
kWkilowatts (power).
VAVoltAmpere (apparent power).
kVAkiloVolt Ampere (apparent power).
varVars (reactive power).
kvarkilovars (reactive power).
AAmperes (current).
VVoltage (r.m.s. AC).
CelsiusDegrees (temperature).
FahrenheitDegrees (temperature).
KDegrees Kelvin (temperature).
PercentPercentage.

7.46. UnlockStatus

Enumeration

Status in response to UnlockConnector.req.

VALUEDESCRIPTION
UnlockedConnector has successfully been unlocked.
UnlockFailedFailed to unlock the connector: The Charge Point has tried to unlock the connector and has detected that the connector is still locked or the unlock mechanism failed.
NotSupportedCharge Point has no connector lock, or ConnectorId is unknown.

7.47. UpdateStatus

Enumeration

Type of update for a SendLocalList.req.

VALUEDESCRIPTION
AcceptedLocal Authorization List successfully updated.
FailedFailed to update the Local Authorization List.
NotSupportedUpdate of Local Authorization List is not supported by Charge Point.
VersionMismatchVersion number in the request for a differential update is less or equal then version number of current list.

7.48. UpdateType

Enumeration

Type of update for a SendLocalList.req.

VALUEDESCRIPTION
DifferentialIndicates that the current Local Authorization List must be updated with the values in this message.
FullIndicates that the current Local Authorization List must be replaced by the values in this message.

7.49. ValueFormat

Enumeration

Format that specifies how the value element in SampledValue is to be interpreted.

VALUEDESCRIPTION
RawData is to be interpreted as integer/decimal numeric data.
SignedDataData is represented as a signed binary data block, encoded as hex data.